Fire Risk Assessment HubIndependent guides to fire risk assessments: the law, costs and choosing a competent assessor
Fire Risk Assessment Hub is an independent guide. We are not a fire and rescue service or any kind of fire authority, and we don't carry out fire risk assessments ourselves. If you ask us to, we'll put you in touch with one fire risk assessor or fire safety consultancy from our partners that covers your area.
Guide · reviewed 14 November 2026

Care home fire risk assessment: evacuation, night staffing and the law

A care home fire risk assessment is the legal fire risk assessment for a building where people sleep and many of them cannot get out without staff. It has to show that the staff on duty, including at night, can move residents away from a fire in time, usually by taking them sideways through fire doors into the next protected area. In England, CQC also asks to see it when a care home applies to register.

  • Who the responsible person is, and where CQC fits in
  • Progressive horizontal evacuation and night staffing
  • What to prepare before the assessor visits

By the Fire Risk Assessment Hub editorial team · Last reviewed

  • Independent guide
  • Free and no obligation
  • For UK businesses, landlords and organisations
  • ICO registration ZA810991

Get a fire risk assessment quote for your care home

Free and no obligation. Takes about a minute.

For UK businesses, landlords and organisations. We aren't a fire authority and we don't carry out assessments ourselves. Your enquiry goes to one partner only, chosen by your postcode and type of premises. Prices and terms are agreed directly with them; there's no obligation.

Care home fire risk assessments: key facts

  • In England and Wales the Fire Safety Order requires a suitable and sufficient fire risk assessment, recorded in full. The care provider, as employer, is normally the responsible person.
  • The Home Office has a specific guide for care homes: Fire safety risk assessment: residential care premises, published under Article 50 of the Fire Safety Order.
  • In care homes, progressive horizontal evacuation is normally adopted: residents near the fire are moved to an adjoining protected area on the same floor.
  • The Home Office guide says the number of beds in each protected area should depend on the minimum number of staff awake, normally the night-time staffing level.
  • You should not depend on the fire and rescue service to evacuate residents. The evacuation plan must work with your own staff.
  • Premises where people sleep must have automatic fire detection.
  • CQC asks care homes applying to register for a copy of their current fire risk assessment, covering PEEPs, medical gas storage and smoking policies. Fire safety law itself is enforced by fire and rescue authorities.
  • In Scotland, government guidance says care home fire drills should take place at least twice a year, with every member of staff taking part at least once a year.

What makes a care home fire risk assessment different?

Residents sleep there, and many cannot escape without staff. So the assessment is less about how fast people can walk out and more about whether the building holds back fire long enough, and whether the staff on shift can move everyone in time.

In an office or shop, a fire risk assessment mostly checks that people can get out quickly by themselves. In a care home that assumption fails. Many residents are frail, some are in bed, some take medication that makes them hard to wake, and some will not understand what the alarm means. The Home Office guide asks you to judge each resident's mobility, their awareness and how much co-operation staff can expect from them.

That changes what the assessment has to answer:

The Home Office makes the same point about assessors. Its 2023 guide says someone with plenty of experience of offices, factories and shops "might not have adequate experience" to assess a residential care home. Experience of care premises is the first thing to check when you choose one.

The risk is real. The Scottish Government's care home guidance recalls the Rosepark Care Home fire in 2004. A short, fast-developing fire started in a cupboard in a bedroom corridor, and 14 residents died from smoke and toxic gases.

Which law applies, and who is the responsible person in a care home?

In England and Wales it is the Regulatory Reform (Fire Safety) Order 2005. The responsible person is normally the care provider as employer, plus anyone else who controls part of the building, such as a landlord.

Under the Fire Safety Order, the responsible person in a workplace is the employer, if the workplace is to any extent under their control. In most care homes that is the registered provider: the company, charity, partnership or individual that runs the service and employs the staff. The registered manager usually runs fire safety day to day, but the duty sits with the organisation.

Others can share duties:

The responsible person must:

  1. Make a suitable and sufficient fire risk assessment, and record it in full, including any group of people especially at risk. In a care home, that is most residents.
  2. Record the name of anyone they engaged to carry out or review it (England and Wales, since 1 October 2023).
  3. Appoint one or more competent people to help with the preventive and protective measures (article 18).
  4. Review the assessment regularly, and whenever something significant changes.
  5. Find out whether anyone else has fire safety duties for the building and share contact details with them.

Local fire and rescue authorities enforce the Fire Safety Order. They can inspect, give advice, and serve alterations, enforcement or prohibition notices. Serious failures can lead to prosecution, with unlimited fines and up to two years in prison.

What does CQC expect, and is CQC the fire safety enforcer?

No. CQC regulates the safety and quality of care; fire safety in buildings is mainly regulated by fire and rescue services. But CQC asks care homes applying to register for a copy of their current fire risk assessment, and it checks premises safety under regulations 12 and 15.

Care home managers often hear about fire safety from two directions. It helps to know who does what.

Fire and rescue authorityCQC (England)
Law it usesRegulatory Reform (Fire Safety) Order 2005Health and Social Care Act 2008 (Regulated Activities) Regulations 2014
Main focusFire safety in the buildingSafety and quality of care, including safe premises
What it can doInspect, serve fire safety notices, prosecuteRefuse registration, take regulatory action

CQC's memorandum of understanding with the National Fire Chiefs Council (signed July 2020) says the primary regulatory responsibility for fire safety in buildings sits with fire and rescue services and local authorities, and responsibility for the safety of care sits with CQC. Fire services may share information with CQC about fires at locations it regulates, and both agree to engage early where they see risks.

CQC still cares about fire safety:

What CQC says a care home's fire risk assessment should cover (registration guidance):

  • Fire hazards, including medical gas storage
  • People at risk
  • Plans for people who need support to evacuate, including PEEPs
  • Policies for smoking on the premises
  • Evaluation of risks and existing fire safety measures
  • Fire alarm systems, extinguishers and other firefighting equipment
  • Fire exits and evacuation routes
  • Staff training
  • Fire drills for staff, people who use the service and visitors
  • An action plan for concerns identified

CQC also says you must complete any actions your fire risk assessment identifies before you apply to register.

Need a care home fire risk assessment?

Tell us about your home and we'll pass your details to one fire risk assessor or fire safety consultancy from our partners that covers your area.

For UK businesses, landlords and organisations. We aren't a fire authority and we don't carry out assessments ourselves. Your enquiry goes to one partner only, chosen by your postcode and type of premises. Prices and terms are agreed directly with them; there's no obligation.

What is progressive horizontal evacuation, and when is it used?

Staff move residents near the fire through a fire-resisting barrier into the next protected area on the same floor. Residents wait there in relative safety, and move further only if needed. The Home Office says it is normally adopted in care homes.

The Home Office residential care guide describes three strategies. A care home may use more than one.

StrategyHow it worksWhen the guide says it fits
Single stage evacuationEveryone leaves the building at onceMainly residents who can leave without help, or with minimal help
Progressive horizontal evacuationResidents move through a fire-resisting barrier to an adjoining protected area on the same level, then further if neededWhere residents depend on staff to help them escape
Delayed evacuationSome residents stay in their room while the fire is dealt withExceptionally, for example where a resident is attached to medical equipment such as oxygen therapy and can't be moved quickly

Delayed evacuation is not a shortcut. The guide says a bedroom used this way needs enhanced structural fire protection, and you still need an evacuation plan for it.

The guide groups residents by how much they rely on staff:

Two rules run through the guide. First, you should not depend on the fire and rescue service to evacuate people. Your strategy must rely only on things within your control. Second, consult your enforcing authority when you plan the strategy.

Timing matters too. The 2023 Home Office guide notes that some premises allow a short investigation before evacuating when a detector goes off by day, and that this "might not be acceptable during the night". Your assessor should check what your fire procedure says about this.

Can your night staff carry out the evacuation plan?

They must be able to. The Home Office guide says beds per protected area should depend on the minimum number of staff awake, normally the night shift, and that staff numbers must always be enough to carry out the emergency plan.

This is the question that most separates a care home assessment from other premises. Rotas are usually set for care needs. The fire risk assessment asks a different question: if a fire starts at 3am, can the people on shift move everyone in the affected area to safety in time?

The Home Office residential care guide says:

Scotland's 2022 guidance is just as direct. A small number of staff cannot be expected to move large numbers of high dependency residents, and difficulties are likely to be worse at night. It says the number of high dependency residents in a sub-compartment should be capable of being evacuated by the staff on duty at night before fire makes evacuation impractical.

Practical points an assessor may raise:

What alarms, compartmentation and fire doors does a care home need?

Almost every care home needs an electrical fire alarm with automatic detectors, sounders and call points. Fire-resisting construction must divide the building into protected areas, and fire doors must close automatically when the alarm sounds.

Detection and warning. The 2023 Home Office guide says premises where people sleep must have automatic fire detection. The residential care guide adds that virtually all premises it covers need an electrical system with automatic detectors, sounders and manual call points. Only very small homes (ground and first floor, up to four residents) may manage with interconnected smoke alarms. In Scotland, government guidance says the normal standard for a care home is a category L1 system under BS 5839-1, meaning automatic detection throughout, including roof spaces and voids.

Compartmentation. Progressive horizontal evacuation only works if each protected area really resists fire and smoke. Assessors look for gaps around pipes and cables, holes left by contractors, damaged ceilings and missing fire stopping in roof voids. The Home Office guide says fires are more frequent during building work, so review the assessment before refurbishment starts.

Fire doors and hold-open devices. Self-closing doors can trap or obstruct residents in daily life, which leads to doors being wedged open. The Home Office guide's answer:

The guide puts it simply: "A care home is not a prison." Fire precautions should not make residents' lives worse than they need to. Good hold-open devices let residents move freely without wedges.

Fire doors take heavy daily wear in care homes from wheelchairs, hoists and trolleys. A damaged door, a broken closer or a missing seal can let smoke into the next protected area, so check them often and fix faults quickly.

Get a fire risk assessment quote for your care home Free and no obligation. Takes about a minute.
Get a fire risk assessment quote

Which fire hazards will an assessor look for in a care home?

Smoking residents, oxygen and other medical gases, laundry, kitchens, electrical equipment, stored linen and aerosols, and bedding used for pressure care. Each has specific guidance in the Home Office care guide.

Expect the assessor to walk every area, including laundry, kitchen, plant rooms, stores and a sample of bedrooms. Agree access in advance so they don't miss anything.

What PEEPs, training and fire drills does a care home need?

Plan how each resident who needs help will be moved, train every member of staff in the evacuation strategy, and run drills that include night staff and night-time conditions.

PEEPs. The Home Office says a suitable emergency plan includes personal emergency evacuation plans for people who may need help to evacuate. The care guide adds that a resident's PEEP may need to be part of their care plan. A useful PEEP covers how the person is alerted, what equipment staff use, how many staff are needed and where the person goes. Update it whenever their needs change.

Training. The 2023 Home Office guide says high-risk premises such as care homes may need more frequent refresher training than the usual annual minimum. The care guide says training should cover:

Drills. The Home Office says drills are likely to be needed at least annually and often more often, and that permanent night shift workers must take part. The care guide advises either one drill at night or one that simulates night conditions with night staffing levels, and including regular respite residents in some drills. In Scotland, guidance says drills should happen at least twice a year, with every staff member taking part at least once a year.

Records to keep

  • The fire risk assessment, every review, and who carried them out
  • Action plan with dates completed
  • PEEPs for each resident who needs help
  • Fire alarm, emergency lighting, extinguisher and door-release tests
  • Drill records: date, time, staff on duty, time taken, problems found
  • Staff training records, including night and agency staff

How do you choose an assessor and prepare for the visit?

Pick an assessor with real care home experience, agree the scope in writing, and have your floor plans, rotas, PEEPs and test records ready. Then act on the findings within the timescales set.

The Home Office says independent certification or registration is particularly important where people sleep or the premises serve vulnerable people. When you compare assessors, ask:

The legal competence requirement for fire risk assessors (article 9A of the Fire Safety Order) is not yet in force. Choosing someone competent is still your responsibility, and the Home Office recommends you keep a record of how you chose. See how to choose a fire risk assessor and what affects the cost.

Before the visit, gather:

  1. Floor plans showing compartments, fire doors and protected areas.
  2. Number of beds per area and current residents' dependency.
  3. Day and night staffing levels.
  4. PEEPs, your fire procedure and evacuation plan.
  5. Service records for alarm, emergency lighting, extinguishers and door hold-open devices.
  6. Drill and training records, plus details of any recent building work.

Reviews. The law doesn't set a fixed interval, but the assessment must be reviewed regularly and whenever something significant changes. Scotland's guidance names changes in residents' dependency, new equipment, alterations and any fire or near miss.

Compare care home fire risk assessment quotes

We'll pass your enquiry to one fire risk assessor or fire safety consultancy from our partners that covers your area.

For UK businesses, landlords and organisations. We aren't a fire authority and we don't carry out assessments ourselves. Your enquiry goes to one partner only, chosen by your postcode and type of premises. Prices and terms are agreed directly with them; there's no obligation.

Are the rules different in Scotland, Wales and Northern Ireland?

Yes. Scotland uses the Fire (Scotland) Act 2005 and has its own care home guidance. Wales uses the Fire Safety Order like England, but has its own care regulator. Northern Ireland has its own fire law and regulator.

Whichever nation you are in, the core questions are the same: can the building contain a fire, can your staff move residents in time at night, and is the plan written down and practised?

Care home fire risk assessments: frequently asked questions

Who is responsible for the fire risk assessment in a care home?

In England and Wales it is the responsible person under the Fire Safety Order. For a care home that is normally the registered provider as employer. A landlord who controls parts of the building, and contractors who maintain fire systems, can share duties for what they control.

Does CQC enforce fire safety in care homes?

No. Fire and rescue authorities enforce fire safety law. CQC regulates the safety and quality of care, asks care homes applying to register for a copy of their fire risk assessment, and checks safe premises under regulations 12 and 15.

What is progressive horizontal evacuation?

Staff move residents near the fire through a fire-resisting barrier into an adjoining protected area on the same floor. Residents wait there while the fire is dealt with, and move further only if needed. The Home Office says it is normally adopted in care homes.

How many night staff does a care home need for fire safety?

No fixed number is set in law. The Home Office guide says the fire risk assessment should identify how many staff are needed to carry out the emergency plan, and the number of beds in each protected area should depend on the minimum number of staff awake, normally the night shift.

Can we wait for the fire service to evacuate residents?

No. The Home Office guide says you should not depend on the fire and rescue service to evacuate people. Your plan must work with your own staff. Scottish guidance says the fire service should only need to rescue residents if the planned evacuation has failed.

Can care home fire doors be held open?

Yes, with the right device. The Home Office guide suggests door closers with an electromagnetic hold-open or free-swing function that release when the fire alarm sounds. Doors must never be wedged, and the guide says doors with these devices should be closed at night.

Does every resident need a PEEP?

Any resident who may need help to evacuate should have one. The Home Office says the emergency plan should include personal emergency evacuation plans for those people, and the care guide says a PEEP may need to be part of the resident's care plan.

How often should care homes hold fire drills?

In England the Home Office says at least annually and often more frequently, with night staff included. The care guide advises a drill at night or one simulating night conditions. Scottish guidance says at least twice a year, with every staff member taking part at least once a year.

How often should a care home fire risk assessment be reviewed?

The law sets no fixed interval but requires regular review, and review whenever something significant changes. In a care home that includes changes in residents' dependency, staffing, layout, building work, or after a fire or near miss. Your assessor should advise on frequency.

Can a care home manager do the fire risk assessment themselves?

The law allows anyone competent to do it. But the Home Office warns that experience of ordinary workplaces may not be enough for a residential care home. Many providers use an assessor with care home experience, and the provider stays legally responsible either way.

Get a fire risk assessment quote for your care home

Free and no obligation. Takes about a minute.

For UK businesses, landlords and organisations. We aren't a fire authority and we don't carry out assessments ourselves. Your enquiry goes to one partner only, chosen by your postcode and type of premises. Prices and terms are agreed directly with them; there's no obligation.

Sources

We checked the facts on this page against these sources on 14 November 2026:

This guide is general information for UK businesses, landlords and organisations, not legal or fire safety advice. Rules differ between England, Wales, Scotland and Northern Ireland. Fire Risk Assessment Hub is an independent guide. We are not a fire and rescue service or any kind of fire authority, and we don't carry out fire risk assessments ourselves. If you ask us to, we'll put you in touch with one fire risk assessor or fire safety consultancy from our partners that covers your area.

Back to the top ↑